Philmore B7005, 5 Amp Push Button Circuit Breaker 32v DC or 250v AC Fuse
"B7000" series circuit breakers are UL 1007 recognized as Supplementary protectors (File E99607) and CSA certified as appliance components protectors (File LR62590). B7000 series are single pole, thermal circuit breakers that feature a recessed reset button which cannot be manually pulled out to disconnect the circuit. When an overload occurs and the breaker opens, it allows the reset button to "pop out" for visible trip indication.
Amps: 5
Max. Resistance: .026 ohms
Trip time @ 200% of Rating: 10-45 seconds
Specifications:
Input Power: 125 VAC / 250 VAC / 50 VDC
Dielectric Strength: 1500 VAC / 1 Minute
Interrupt Capacity: 125 VAC x 1000 A, 250 VAC x 2000 A
Insulation Resistance: > 100 M
Calibration:
25 C-100% of rated current continuously carried
25 C-between 101% to 145% - may trip or not
25 C-150% of rated current - trip within 1 hour
25 C-200% of rated current - trip within 1 minute
Contact Endurance: 125 VAC x 150% of rated current - 500 cycles
3A -50A: Spade Terminals
60A - 90A: Screw Terminals